Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Abstracts
Cardiovascular, Case Report
Cardiovascular, Commentary
Cardiovascular, Editorial
Cardiovascular, Guest Editorial
Cardiovascular, Images in Cardiology
Cardiovascular, Interventional Round
Cardiovascular, Original Article
Cardiovascular, Perspective Review
Cardiovascular, Preface
Cardiovascular, Review Article
Cardiovascular, Student’s Corner
Case Report
Case Report, Cardiovascular
Case Reports
Case Series, Cardiovascular
Clinical Discussion
Clinical Rounds
CPC
Current Issue
Debate
Dedication
Editorial
Editorial Cardiovascular
Editorial, From the Publisher’s Desk
Expert Comments
Expert's Opinion
Genetic Autopsy
Genetics Autopsy
Guest Editorial, Cardiovascular
Image in Cardiology
Images in Cardiology
Images in Cardiology, Cardiovascular
Interventional Round
Interventional Round, Cardiovascular
Interventional Rounds
Letter to Editor
Letter to Editor, Clinical Cardiology
Letter to the Editor
Media and news
Original Article
Original Article, Cardiovascular
Original Article, Cardiovascular Health
Practice in Medicine
Preface
Review Article
Review Article, Cardiovascular
Scientific Paper
Short Communication
Student's Corner
Supplementary
Supplemetary
WINCARS Activities
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Abstracts
Cardiovascular, Case Report
Cardiovascular, Commentary
Cardiovascular, Editorial
Cardiovascular, Guest Editorial
Cardiovascular, Images in Cardiology
Cardiovascular, Interventional Round
Cardiovascular, Original Article
Cardiovascular, Perspective Review
Cardiovascular, Preface
Cardiovascular, Review Article
Cardiovascular, Student’s Corner
Case Report
Case Report, Cardiovascular
Case Reports
Case Series, Cardiovascular
Clinical Discussion
Clinical Rounds
CPC
Current Issue
Debate
Dedication
Editorial
Editorial Cardiovascular
Editorial, From the Publisher’s Desk
Expert Comments
Expert's Opinion
Genetic Autopsy
Genetics Autopsy
Guest Editorial, Cardiovascular
Image in Cardiology
Images in Cardiology
Images in Cardiology, Cardiovascular
Interventional Round
Interventional Round, Cardiovascular
Interventional Rounds
Letter to Editor
Letter to Editor, Clinical Cardiology
Letter to the Editor
Media and news
Original Article
Original Article, Cardiovascular
Original Article, Cardiovascular Health
Practice in Medicine
Preface
Review Article
Review Article, Cardiovascular
Scientific Paper
Short Communication
Student's Corner
Supplementary
Supplemetary
WINCARS Activities
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Abstracts
Cardiovascular, Case Report
Cardiovascular, Commentary
Cardiovascular, Editorial
Cardiovascular, Guest Editorial
Cardiovascular, Images in Cardiology
Cardiovascular, Interventional Round
Cardiovascular, Original Article
Cardiovascular, Perspective Review
Cardiovascular, Preface
Cardiovascular, Review Article
Cardiovascular, Student’s Corner
Case Report
Case Report, Cardiovascular
Case Reports
Case Series, Cardiovascular
Clinical Discussion
Clinical Rounds
CPC
Current Issue
Debate
Dedication
Editorial
Editorial Cardiovascular
Editorial, From the Publisher’s Desk
Expert Comments
Expert's Opinion
Genetic Autopsy
Genetics Autopsy
Guest Editorial, Cardiovascular
Image in Cardiology
Images in Cardiology
Images in Cardiology, Cardiovascular
Interventional Round
Interventional Round, Cardiovascular
Interventional Rounds
Letter to Editor
Letter to Editor, Clinical Cardiology
Letter to the Editor
Media and news
Original Article
Original Article, Cardiovascular
Original Article, Cardiovascular Health
Practice in Medicine
Preface
Review Article
Review Article, Cardiovascular
Scientific Paper
Short Communication
Student's Corner
Supplementary
Supplemetary
WINCARS Activities
View/Download PDF

Translate this page into:

Case Report
04 (
03
); 146-149
doi:
10.1055/s-0039-3399617

Case Report: Case of Coronary Stent Longitudinal Deformation

Department of Cardiology, Nizam’s Institute of Medical Sciences, Panjagutta, Hyderabad, India

Suresh Yerra, DM (Cardiology) Department of Cardiology, Nizam’s Institute of Medical Sciences Panjagutta, Hyderabad, 500082 India Yerrasuresh3@gmail.com

Licence
This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)
Disclaimer:
This article was originally published by Thieme Medical and Scientific Publishers Private Ltd. and was migrated to Scientific Scholar after the change of Publisher.

Abstract

Abstract

The foreshortening of a stent also known as longitudinal stent deformation (LSD) is a potential complication of present generation drug-eluting stents (DES) that had thin struts design, and it was most commonly reported in the everolimus-eluting Promus Element stent. However, there are limited reports of migration and dislodgement of a DES shortly after its deployment. So, we describe a case of a DES foreshortening 1 and half months after its deployment. While performing complex interventions, careful handling and gentle manipulation of procedure-related devices and use of imaging modalities such as optical coherence tomography, intravascular ultrasound, and adjunctive balloons for complete lesion cover and optimal stent apposition may significantly reduce the occurrence of LSD and related complications.

Keywords

longitudinal stent deformation (LSD)
drug-eluting stents (DES)
quantitative coronary analysis (QCA)
bioabsorbable polymeric scaffolds (BRS)

Introduction

The foreshortening of a stent also known as longitudinal stent deformation (LSD) is a potential complication of present generation drug-eluting stents (DES) that had thin struts design, and it was most commonly reported in the everolimus-eluting Promus Element stent. It has also been reported intermittently in other types of stent platforms, thereby suggesting that there might be risk factors other than the stent design for LSD.1 2 3 However, there is limited existing data on the most predominant predictors of LSD, which was defined by quantitative methods such as the quantitative coronary analysis (QCA) and unclear long-term clinical implication of LSD. Stent migration and embolization are a rare complication of coronary intervention and might create a stressful situation for the operators/interventional cardiologists.4 5 6 In post cardiopulmonary resuscitation7 cases, there are case reports that showed complications such as distortion, compression, dislodgement, and migration of large endovascular stents. Multiple trials have showed that increased rate of stent deformation result in stent thrombosis with bioabsorbable polymeric scaffolds (BRS)8 9 and it may be explained by malapposition from weak polymer materials in BRS and result in asymmetric material degradation from microstructural damage due to local stress concentration from the stent crimping, which is less often reported in stents with nonabsorbable polymeric scaffolds. However, there are limited reports of migration and dislodgement of a DES shortly after its deployment. So, we describe a case of a DES foreshortening (LSD) 1 and half months after its deployment.

Case Details

A 44-year-old male patient reformed smoker and occasional alcoholic with no comorbidities presented to a private hospital at Khammam with acute inferior wall ST-elevation myocardial infarction. He underwent coronary angiogram that showed double vessel disease (left anterior descending\right coronary artery [LAD/RCA]), following which he underwent primary percutaneous coronary intervention (PCI) to RCA on 21 May 2019 (Figs. 1 2). In June 2019, patient was referred to our institute for the residual lesion (LAD) revascularization. The patient was asymptomatic at the time of presentation. He underwent a coronary angiogram, which showed complete occlusion of the RCA stent and stenosis proximal to the RCA stent. On comparing with the previous PCI angiograms with the present coronary angiography views and QCA, it was suggestive of the stent foreshortening (LSD) and doubtful short distance migration (Figs. 3 4); as the details of the previously deployed stent were not available with the patient, we could not calculate the QCA of the initially deployed stent. We can notice that both longitudinal and horizontal deformation had occurred along with a mild degree of stent migration. The patient underwent PCI to LAD and subsequently planned PCI to RCA. With the help of fine cross coronary microguide catheter and Asahi Gaia 2 wire proximal RCA lesion was crossed and predilated sequentially with 10 × 10 mm, 1.5 × 10 mm Tazuna balloons and 30 × 17 mm Apollo NC balloon and stented with Xience Xpedition 3.0 × 48 mm DES (Fig. 5).

Fig. 1 Angiographic view of right coronary artery at the time of initial presentation with inferior wall myocardial infarction.

Fig. 1 Angiographic view of right coronary artery at the time of initial presentation with inferior wall myocardial infarction.

Fig. 2 Positioning of a stent with the help of balloon markers (arrows) and final angiographic view after stent deployment.

Fig. 2 Positioning of a stent with the help of balloon markers (arrows) and final angiographic view after stent deployment.

Fig. 3 Coronary angiogram done 1 and a half month after right coronary artery stent deployment.

Fig. 3 Coronary angiogram done 1 and a half month after right coronary artery stent deployment.

Fig. 4 Quantitative coronary analysis. Length: 12.51 mm; minimum diameter: 1.82; maximum diameter: 4.30; mean diameter: 2.85.

Fig. 4 Quantitative coronary analysis. Length: 12.51 mm; minimum diameter: 1.82; maximum diameter: 4.30; mean diameter: 2.85.

Fig. 5 Final angiographic views after restenting the proximal right coronary artery.

Fig. 5 Final angiographic views after restenting the proximal right coronary artery.

Discussion

The multiple studies have shown that ballooning or stenting of the provisional side branch, downstream complex intervention, and use of imaging devices such as optical coherence tomography (OCT) and intravascular ultrasound (IVUS) were the predictors and shown to be independently associated with LSD based on QCA. Arnous et al10 have shown that multivessel stenting, the use of GuideLiner catheter, and postdilation ballooning were the predictors of LSD. Use of extra support guidewire or guiding catheter for complex PCIs or passage of a second stent had been significantly associated with LSD in another study.1 In addition, aggressive manipulation of guiding catheter, use of imaging-guided PCI under OCT or IVUS, and serial dilation with multiple balloons have been suggested as major predictors associated with the occurrence of LSD.11 12

In cases of nonapposition of the proximal portion of the stent to the vessel wall, use of secondary devices in such cases may increase the chance of contact with unopposed struts especially when wire bias exists resulting in the occurrence of LSD.10 Studies have shown that careful handling and gentle manipulation of procedure-related devices such as guiding catheters, backup supporting catheters, OCT, IVUS, and adjunctive balloons may significantly reduce the occurrence of LSD. Stents deployed in LMCA and Osteo-Proximal LAD are more prone to LSD by longitudinal forces, because of frequent malapposition of stents due to the under-sizing of stents, and because of the frequent contact with the guiding catheter during insertion and pullback of various supporting devices, it is especially common when there is poor alignment of the stent with the coronary artery.10 13 Theoretically, LSD could result in malapposition of the stent and incomplete coverage of plaque-causing early stent thrombosis and in-stent restenosis, which may account for the higher incidence of complications and adverse clinical outcomes.

Detection of subtle LSD by visual estimation of angiography is difficult, and it may result in incomplete lesion coverage and deformation of malapposed stent struts when angiographically nonsignificant LSD occurs. Therefore, confirmation of optimal stent apposition and complete lesion cover by the stent may minimize the future adverse events when LSD is suspected. Coronary stent migration and dislodgment are a critical complication of PCI rarely occurring with incidence varying between 0.31 and 8.2%. Dislodgement of the stent from the stent-balloon assembly unit can occur during the pullback, into the guide catheter before stent deployment. Complex coronary interventions and extremely angulated, highly calcified plaques with inadequate predilation or interference from previously deployed stents are more prone to this complication. There are reports of coronary artery stent displacement during PCI with the use of intracoronary vasodilator drugs such as nitroglycerine.14 Incidence of LSD has been decreasing with the development of advanced hardware and improved PCI techniques; however, we continued to see reports of LSD, stent migration, and embolization with the use of premounted DES during PCI.4 15 16 In this case, we had noticed that both longitudinal and horizontal deformation of the previously deployed stent has occurred along with mild stent migration. Horizontal deformation of the implanted stent is known to occur at the native tightest portion of the stent, which had been demonstrated in this case also. Because of this, the stent was not covered in the native tightest site, leading to total occlusion at that site. This is the first case in our experience regarding LSD, horizontal deformation, and short-distance migration of a DES within 1 and half months after its deployment.

Limitations

Details of the previously deployed stent details are not known to know its exact size, and we could not calculate the QCA that is a predominant limitation of this case report, and due to the financial limitations of the patient, we could not use intracoronary imaging devices such as OCT/IVUS to know the exact cause of stent deformation that is another predominant limitation.

Conclusion

LSD, horizontal deformation, dislodgement, and migration of coronary stents are infrequent, but critical complications of coronary interventions. Complex coronary interventions with highly calcified lesions and extremely angulated vessels are more prone to such complications. Hence, while performing such interventions careful handling and gentle manipulation of procedure-related devices and use of imaging modalities such as OCT, IVUS, and adjunctive balloons for complete lesion cover and optimal stent apposition may significantly reduce the occurrence of LSD and related complications. As the horizontal deformation of the stent is known to occur at the native tightest portion of the stent that has been demonstrated in this case, careful pre- and postdilation is required with appropriate size, noncompliant balloons to achieve optimal results thereby minimizing such complications.

Conflict of Interest

None declared.

References

  1. , , , et al . Clinical, angiographic and procedural characteristics of longitudinal stent deformation. Int J Cardiovasc Imaging. 2016;32(08):1163-1170.
    [Google Scholar]
  2. , , . Longitudinal compression: a “new” complication with modern coronary stent platforms–time to think beyond deliverability? EuroIntervention. 2011;7(07):872-877.
    [Google Scholar]
  3. , , . Longitudinal stent deformation: insights on mechanisms, treatments and outcomes from the Food and Drug Administration Manufacturer and User Facility Device Experience database. EuroIntervention. 2012;8(02):196-204.
    [Google Scholar]
  4. , , , et al . Coronary and systemic stent embolization during percutaneous coronary interventions: a single center experience. Int Heart J. 2007;48(02):129-136.
    [Google Scholar]
  5. , , . Successful coronary stent retrieval from the saphenous vein graft to right coronary artery. Case Rep Med. 2009;2009:718685.
    [Google Scholar]
  6. , , , et al . Stent deployment failure: reasons, implications, and short- and long-term outcomes. Catheter Cardiovasc Interv. 2003;59(03):324-328.
    [Google Scholar]
  7. , , , et al . Compression, distortion and dislodgement of large caliber stents in congenital heart defects caused by cardiopulmonary resuscitation: a case series and review of the literature. Clin Res Cardiol. 2014;103(09):719-725.
    [Google Scholar]
  8. , , , et al . Neoatherosclerosis 5 years after bioresorbable vascular scaffold implantation. J Am Coll Cardiol. 2018;71(17):1882-1893.
    [Google Scholar]
  9. , , , , , , . Fully bioresorbable vascular scaffolds: lessons learned and future directions. Nat Rev Cardiol. 2019;16(05):286-304.
    [Google Scholar]
  10. , , , et al . Incidence and mechanisms of longitudinal stent deformation associated with Biomatrix, Resolute, Element, and Xience stents: angiographic and case-by-case review of 1,800 PCIs. Catheter Cardiovasc Interv. 2015;86(06):1002-1011.
    [Google Scholar]
  11. , , , et al . Mechanical complications of everolimus-eluting stents associated with adverse events: an intravascular ultrasound study. EuroIntervention. 2014;9(11):1301-1308.
    [Google Scholar]
  12. , , . Longitudinal stent shortening: the long and short of it!! Catheter Cardiovasc Interv. 2013;81(05):818-819.
    [Google Scholar]
  13. , , , et al . Longitudinal stent deformation: a retrospective analysis of frequency and mechanisms. EuroIntervention. 2012;8(02):267-274.
    [Google Scholar]
  14. , , , . Migration of fully deployed stent after intracoronary glyceryl trinitrate administration: an unusual percutaneous coronary intervention complication. Pak J Med Sci. 2013;29(03):863-865.
    [Google Scholar]
  15. , , , et al . Incidence, retrieval methods, and outcomes of stent loss during percutaneous coronary intervention: a large single-center experience. Catheter Cardiovasc Interv. 2005;66(03):333-340.
    [Google Scholar]
  16. , , , et al . Nonsurgical retrieval of embolized coronary stents. Catheter Cardiovasc Interv. 2000;51(04):432-440.
    [Google Scholar]
Show Sections