Prenatal Detection of Congenital Heart Disease by Routine Fetal Echocardiography in Consecutive Pregnancies
Article History
-
Received: ,
Accepted: ,
,
Abstract
Objectives:
Early prenatal detection of congenital heart disease (CHD) using fetal echocardiography (FE) facilitates comprehensive prenatal evaluation, multidisciplinary perinatal planning, and timely postnatal management, improving outcomes. This study assessed FE for detecting major and complex CHD and identified cases that would have been missed using a risk-based referral strategy.
Materials and Methods:
A hospital-based prospective observational study was undertaken at a tertiary care teaching institution from June 2023 to January 2024. A total of 120 pregnant women between 15 and 35 weeks of gestation underwent FE irrespective of maternal or fetal risk factors. All live-born neonates underwent postnatal transthoracic echocardiography, which served as the reference standard for diagnostic accuracy.
Results:
FE detected complex CHD in 11 of the 120 fetuses (9.2%). Of these, nine pregnancies underwent medical termination, whereas two continued to delivery. Postnatal echocardiography was performed in 111 live-born neonates and identified CHD in 22 (19.8%), predominantly minor acyanotic lesions. Compared with the routine screening group, the high-risk group demonstrated a significantly higher detection rate of complex CHD (25.0% vs. 4.3%, p = 0.001). However, routine screening identified four additional cases of complex CHD that would have been missed by high-risk referral alone. FE demonstrated good diagnostic performance for detecting complex CHD, although small ventricular septal defects were not detected prenatally. The number screened to detect one additional case of complex CHD was 23.
Conclusion:
FE enabled prenatal detection of complex CHD, including additional cases among pregnancies undergoing routine screening without recognized risk factors. These findings support its potential role in prenatal CHD detection.
Keywords
How to cite this article: Gayathri AR, Varun P, Kasturi S, Thejaswi P, Vanajakshamma V. Prenatal Detection of Congenital Heart Disease by Routine Fetal Echocardiography in Consecutive Pregnancies. Indian J Cardiovasc Dis Women. doi: 10.25259/IJCDW_44_2026

INTRODUCTION
Congenital heart disease (CHD) is among the most common congenital anomalies, with a global birth prevalence estimated at approximately 9.3/1,000 live births, and remains a major cause of neonatal morbidity and mortality.[1,2] Although considerable progress has been made in the medical and surgical management of CHD, it remains a major cause of morbidity and mortality in early life. To improve neonatal outcomes and ensure timely intervention, it is vital to obtain a prenatal diagnosis as early as possible.
Fetal echocardiography (FE) has become the primary method for detecting structural cardiac anomalies during pregnancy.[3] Current screening targets high-risk pregnancies.[4,5] However, many CHD cases occur in pregnancies without identifiable risk factors.
Current guidelines recommend performing comprehensive FE between 18 and 22 weeks of gestation. However, its diagnostic performance remains highly dependent on operator expertise, and certain cardiac anomalies may be overlooked, particularly in low-risk pregnancies.[6,7] As a result, the majority of CHD cases may go undetected, delaying diagnosis and treatment.
This study evaluated major or complex CHD using FE in a consecutive cohort of pregnant women, and the secondary analysis aimed to identify CHDs missed by risk-based referral by correlating with postnatal outcomes.
MATERIALS AND METHODS
A prospective observational study was undertaken at a tertiary care teaching hospital between June 2023 and January 2024. All consecutive pregnant women referred for FE during the study period were included without restriction based on referral indication or maternal and fetal risk status. All study participants signed the pre-conception and pre-natal diagnostic techniques (PCPNDT) form, and informed consent was obtained following approval from the Institutional Ethics Committee.
Inclusion and exclusion criteria
Pregnant women aged >18 years with singleton pregnancies between 15 and 35 weeks of gestation who consented to participate in the study were included.
Fetuses with extracardiac anomalies incompatible with life, those lost to postnatal follow-up, and twin pregnancies were excluded from the study. The exclusion of twin pregnancies was due to the technical limitations of FE, altered hemodynamics, and the increased risk of confounding neonatal complications, which may affect the accurate assessment of CHD.
A total of 120 pregnant women at 15–35-week gestation were enrolled, including routine and high-risk referrals irrespective of risk status, resulting in a mixed rather than exclusively high-risk cohort. Demographic, parental, obstetric, and clinical data, FE findings, and postnatal outcomes were systematically recorded in Excel.
FE was performed by an experienced pediatric cardiologist using a Philips EPIQ 7 ultrasound system (Philips Medical Systems International BV, USA) equipped with a C5-1 curvilinear transducer (3.5–5 MHz). The examination was conducted in accordance with the International Society of Ultrasound in Obstetrics and Gynaecology guidelines and included a comprehensive assessment of the standard fetal cardiac views, namely the four-chamber view, left ventricular outflow tract, right ventricular outflow tract, three-vessel view, three-vessel and trachea view, aortic arch, ductal arch, and bicaval view, using both grayscale imaging and color Doppler. Pulsed Doppler was used to assess inflow and outflow velocities. Fetal heart rate and rhythm were assessed in all fetuses using M-mode and pulsed Doppler evaluation. A fetus with a heart rate below 110 beats/min was defined as having bradycardia, whereas a fetus with a heart rate above 160 beats/min was defined as having tachycardia.[8]
The average duration of the fetal echocardiographic examination was approximately 30–40 min depending on fetal position and the complexity of the findings, with repeat imaging when initial quality was suboptimal. All diagnoses were established in a single session. However, follow-up evaluations were required in pregnancies diagnosed with major CHD after a 6–8-week interval for valve evaluation and peripartum planning.
The suspected CHDs were classified as either complex or minor. A congenital heart anomaly was considered complex when it involved cardiac structures that are essential for maintaining life.[9] For the primary outcome analysis, neonates with small atrial septal defects (ASD) or patent ductus arteriosus (PDA) detected during the early postnatal period were considered to have physiological or minor acyanotic cardiac findings rather than complex CHD and were therefore excluded from the analysis. In pregnancies diagnosed with major CHD, detailed prognostic outcomes and relevant information about the condition with multidisciplinary counseling were provided, and decisions regarding continuation or termination of pregnancy were made by the parents.
Postnatal echocardiography
All live-born neonates of the study participants underwent postnatal transthoracic echocardiography using a Philips EPIQ 7 (Philips Medical Systems International BV, USA) echocardiography machine with S8 and S12 linear transducers in accordance with the recommendations of the American Society of Echocardiography by a cardiologist blinded to the prenatal findings. Neonates with normal FE findings were evaluated within 1 month. All surviving neonates with CHD underwent serial clinical and echocardiographic follow-up assessing disease progression and need for surgical or catheter-based intervention.
Statistical analysis
Statistical analyses were performed using IBM Statistical Package for the Social Sciences Statistics for Windows, version 25.0 (IBM Corp., Armonk, NY, USA). Categorical variables were summarized as frequencies and percentages, and continuous variables as mean ± standard deviation. Groups were compared using the Chi-square or Fisher’s exact test, as appropriate. Among the 111 live-born neonates who underwent postnatal echocardiography, the diagnostic performance of FE was assessed using echocardiography as the reference standard, with sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) reported with 95% confidence intervals (CIs). The number screened per additional complex CHD detected was calculated as a descriptive measure of incremental case detection. A two-sided p < 0.05 was considered statistically significant.
RESULTS
Over a study period of 8 months, a total of 120 pregnant women were enrolled. The maternal age ranged from 18 to 40 years, with a gestational age at evaluation between 15 and 35 weeks. The average fetal heart rate at the time of examination was 149 beats/min; no sustained fetal bradyarrhythmia or tachyarrhythmia was identified in the fetuses. Among them, 28 (23.3%) were classified as high-risk based on standard referral indications, and 92 (76.7%) underwent routine screening. The baseline characteristics of the routine screening and high-risk groups are summarized in Table 1.
| Characteristic | Routine screening (92) n (%) | High-risk group (28) n (%) | Total (120) |
|---|---|---|---|
| Maternal age (Mean ± SD) | 26.08±4.6 | 27.36±5.42 | 26.38±4.81 |
| Consanguinity present | 19 (20.6) | 9 (32.1) | 28 (23.3) |
| Primigravida | 45 (48.9) | 11 (39.3) | 56 (46.7) |
| Gravida 2 | 26 (28.2) | 06 (21.4) | 32 (26.6) |
| Gravida 3 | 16 (17.4) | 04 (14.3) | 20 (16.6) |
| Gravida 4 | 04 (4.3) | 04 (14.3) | 08 (6.6) |
| Gravida 5 | 01 (1.1) | 03 (10.7) | 04 (3.3) |
| History of no abortion | 72 (78.3) | 18 (64.3) | 90 (75) |
| History of 1 abortion | 15 (16.3) | 03 (10.7) | 18 (15) |
| History of 2 and more abortions | 05 (5.4) | 07 (25) | 12 (10) |
| History of maternal CHD | 0 | 10 (35.7) | 10 (8.3) |
| Maternal hypertension | 0 | 04 (14.2) | 04 (3.3) |
| Maternal diabetes mellitus | 0 | 03 (10.7) | 03 (2.5) |
| Maternal hypothyroidism | 0 | 11 (39.2) | 11 (9.2) |
| Mode of conception (natural) | 90 (97.8) | 24 (85.7) | 114 (95) |
| Mode of conception (IVF) | 02 (2.17) | 04 (14.2) | 06 (5) |
| FE Findings normal | 88 (95.6) | 21 (75) | 109 (90.8) |
| FE Findings abnormal | 04 (4.3) | 07 (25) | 11 (9.2) |
CHD: Congenital heart disease, IVF: In vitro fertilization, FE: Fetal echocardiography, SD: Standard deviation
CHD was detected in 11 fetuses, yielding a prevalence of 9.2%. This includes hypoplastic left heart syndrome, tetralogy of Fallot, and other structural anomalies as reported in Table 2. Representative FE images are shown in Figures 1 and 2. Of these 11 prenatally diagnosed cases, 9 pregnancies underwent medical termination of pregnancy, while 2 pregnancies continued to delivery [Table 3].
| Complex CHD | Number (n) | Percentage n/11 |
|---|---|---|
| DORV with VSD pulmonary atresia | 3 | 27.3 |
| DTGA | 2 | 18.2 |
| TOF | 1 | 9.1 |
| VSD with PS | 1 | 9.1 |
| Single ventricle | 1 | 9.1 |
| Truncus arteriosus | 1 | 9.1 |
| HLHS | 1 | 9.1 |
| Common atrium with severe AVVR | 1 | 9.1 |
DORV: Double outlet right ventricle, DTGA: Dextro transposition of great arteries, TOF: Tetralogy of Fallot, VSD with PS: Ventricular septal defect with pulmonary stenosis, HLHS: Hypoplastic left heart syndrome, AVVR: Atrioventricular valve regurgitation, CHD: Congenital heart disease


| Type of CHD | Number (n) | Percentage n/9 |
|---|---|---|
| DORV with VSD pulmonary atresia | 3 | 33.3 |
| DTGA | 2 | 22.2 |
| Single ventricle | 1 | 11.1 |
| Truncus arteriosus | 1 | 11.1 |
| HLHS | 1 | 11.1 |
| Common atrium with severe AVVR | 1 | 11.1 |
DORV: Double outlet right ventricle, DTGA: Dextro transposition of great arteries, HLHS: Hypoplastic left heart syndrome, AVVR: Atrioventricular valve regurgitation, CHD: Congenital heart disease, MTP: Medical termination of pregnancy, VSD: ventricular septal defect
The remaining 111 live-born neonates underwent postnatal echocardiographic evaluation, and CHD was identified in 22 cases (19.8%), predominantly with acyanotic lesions as listed in Table 4. FE accurately detected all prenatally identified complex CHDs. However, it failed to detect small ventricular septal defects and physiological shunts such as ASD and PDA, which were identified postnatally. These lesions were considered physiological or minor acyanotic findings and were excluded from the analysis of complex CHD detection accuracy.
| Type of CHD | Number (n) | Percentage n/111 |
|---|---|---|
| ASD | 8 | 7.20 |
| VSD | 6 | 5.40 |
| PDA | 6 | 5.40 |
| TOF | 1 | 0.90 |
| VSD with PS | 1 | 0.90 |
ASD: Atrial septal defect, VSD: Ventricular septal defect, PDA: Patent ductus arteriosus, TOF: Tetralogy of Fallot, VSD with PS: Ventricular septal defect, PS: Pulmonary stenosis, CHD: Congenital heart disease
Compared with the routine screening group, the high-risk group exhibited a significantly greater detection rate of complex CHD (25.0% [7/28] vs. 4.3% [4/92]; χ2 = 10.99, p = 0.001; Fisher’s exact test, p = 0.003) [Table 5]. Despite the higher prevalence in the high-risk group, four of the 11 cases (36.4%) were detected in the routine screening (low-risk) group. These four cases would have been missed if screening was limited to high-risk pregnancies alone. The distribution of maternal risk factors for FE is presented in Figure 3. Figure 4 illustrates the detection rate of complex CHD between the two screening groups.
| Screening group | Complex CHD detected | Total | Statistical test | |
|---|---|---|---|---|
| Present, n (%) | Absent, n (%) | |||
| Routine screening | 4 (4.3) | 88 (95.7) | 92 | Chi-square=10.99 p=0.001 Fisher’s exact test p=0.003 |
| High-risk group | 7 (25.0) | 21 (75.0) | 28 | |
| Total | 11 (9.2) | 109 (90.8) | 120 | |
CHD: Congenital heart disease. Bold formatting of p value here indicates a statistical significance.


Diagnostic performance was evaluated among the 111 live-born neonates, with postnatal echocardiographic confirmation available for the identified complex CHD cases. The nine terminated pregnancies were excluded from this assessment because postnatal confirmation was not available. Using this as the reference standard, FE demonstrated a sensitivity of 100% (95% CI: 15.8–100%), specificity of 100% (95% CI: 96.7–100%), PPV of 100% (95% CI: 15.8–100%), and NPV of 100% (95% CI: 96.7–100%) with wide CI due to the small number of confirmed complex CHD cases (n = 2). Figure 5 shows 2 × 2 contingency table for diagnostic accuracy analysis.

The number screened per additional complex CHD detected was calculated by dividing the number of women undergoing routine screening by the additional complex CHD cases identified in this group. Among 92 women undergoing routine screening, four additional cases of complex CHD were detected, yielding a value of 23 (92/4), corresponding to 23 women screened per additional case of complex CHD detected beyond those identified through high-risk referral. The derivation of number screened per additional complex CHD is presented in Table 6, and the formula used for calculating is presented below.
| Parameter | Value |
|---|---|
| Total women in the routine screening group | 92 |
| Complex CHD detected in the routine screening group | 4 |
| Additional complex CHD detected exclusively through routine screening | 4 |
| Formula |
|
CHD: Congenital heart disease
DISCUSSION
CHD contributes substantially to neonatal deaths due to complex congenital anomalies.[10,11] Despite advances in neonatal care and cardiac surgery, critical CHD remains a major cause of neonatal morbidity and mortality, often presenting after closure of fetal shunts.
This highlights the vital need for prenatal diagnosis, where FE serves as the gold standard imaging modality for the detection, classification, and management of CHD.[12] Among the 111 live births available for outcome assessment, the screening approach demonstrated 100% sensitivity, specificity, PPV, and NPV. However, independent postnatal echocardiographic verification was available for only two cases of complex CHD. The nine terminated pregnancies were not included in the diagnostic accuracy assessment because postnatal confirmation was unavailable. FE may facilitate early detection of complex CHD, prenatal counseling, delivery planning, and timely postnatal management. Critical CHD comprises approximately one-third of all CHD cases and often requires early intervention.[13,14] Evidence suggests that prenatally diagnosed neonates experience improved surgical outcomes, reduced preoperative morbidity, and enhanced long-term survival.[15,16]
High-risk versus routine screening
Selective screening based solely on high-risk criteria may miss affected fetuses. In this study, the prevalence of prenatally detected complex CHD (9.2%) and overall postnatal CHD (19.8%) exceeded that reported in general population studies. The higher CHD prevalence observed in this study may reflect the tertiary referral setting, small sample size, and universal postnatal echocardiographic evaluation, which enabled identification of asymptomatic lesions such as ASD, VSD, and PDA. Importantly, the primary prenatal outcome was complex CHD rather than all congenital cardiac abnormalities. The additional postnatal findings not detected prenatally highlight the limitations of FE in identifying small septal defects and physiological neonatal shunts. Therefore, the diagnostic performance reported should be interpreted specifically for complex CHD and not extrapolated to all forms of CHD.
However, routine screening identified four complex CHDs that would have been completely missed if only high-risk pregnancies were screened. Indian and international studies report 70–90% of CHDs in low-risk pregnancies.[17] Thus, selective referral fails to capture a large proportion of clinically significant cases.
Our findings align with this study, which highlighted that nearly half of CHDs occurred in low-risk women.[18] Western literature reported that anomaly scans detect only 40–60% of anomalies, influenced by operator expertise.[19] This reinforces that targeted high-risk screening, while efficient, is insufficient for achieving optimal detection.
The number screened per additional complex CHD detected was 23, representing a descriptive, cohort-specific measure of incremental detection. As this was an observational study and women were not randomly assigned to routine or risk-based screening, this value represents the observed difference in detection within the study cohort, so this measure should not be interpreted as demonstrating the superiority of one screening strategy over the other.
Strengths and limitations
This prospective single-center study included a consecutive cohort with postnatal correlation. However, its small sample size, operator dependence, and referral bias may limit generalizability. Limited follow-up restricted analysis of prematurity and persistent shunts; consecutive inclusion minimized selection bias, although referral bias remained possible.
CONCLUSION
FE enabled prenatal detection of complex CHD, including additional cases among pregnancies undergoing routine screening without recognized risk factors. These findings support its potential role in prenatal CHD detection, while larger prospective multicenter studies are needed to establish its clinical effectiveness and comparative benefit over risk-based screening.
Ethical approval:
The research/study was approved by the Institutional Review Board at Sri Venkateswara Institute of Medical Sciences, Tirupathi, number AS/11/IEC/SVIMS/2017-1455, dated August 09, 2023.
Declaration of patient consent:
The authors certify that they have obtained all appropriate patient consent forms. In the form, the patient has given consent for their images and other clinical information to be reported in the journal. The patient understands that the patient’s names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.
Conflicts of interest:
There are no conflicts of interest.
Use of artificial intelligence (AI)-assisted technology for manuscript preparation:
The authors confirm that there was no use of artificial intelligence (AI)-assisted technology for assisting in the writing or editing of the manuscript and no images were manipulated using AI.
Financial support and sponsorship: Nil.
References
- Birth prevalence of congenital heart disease worldwide: A systematic review and meta-analysis. J Am Coll Cardiol. 2011;58:2241-7.
- [CrossRef] [PubMed] [Google Scholar]
- Incidence and risk factors of congenital heart disease in Qingdao: A prospective cohort study. BMC Public Health. 2021;21:1044.
- [CrossRef] [PubMed] [Google Scholar]
- Fetal echocardiography findings and postnatal outcomes: Are there significant changes? Kosuyolu Heart J. 2025;28:113-8.
- [CrossRef] [Google Scholar]
- Guidelines and recommendations for performance of the fetal echocardiogram: An update from the American society of echocardiography. J Am Soc Echocardiogr. 2023;36:679-723.
- [CrossRef] [PubMed] [Google Scholar]
- Indications for fetal echocardiography: Consensus and controversies among evidence-based national and international guidelines. Ultrasound Obstet Gynecol. 2025;65:682-93.
- [CrossRef] [PubMed] [Google Scholar]
- ISUOG practice guidelines (updated): Fetal cardiac screening. Ultrasound Obstet Gynecol. 2023;61:788-803.
- [CrossRef] [PubMed] [Google Scholar]
- MicroRNAs as novel biomarkers for prenatal fetal congenital heart disease-systematic literature review. Front Genet. 2025;16:1628632.
- [CrossRef] [PubMed] [Google Scholar]
- Fetal Heart Rate Classifications. Addendum to Intrapartum Care: Care for Healthy Women and Babies In: National Institute for Health and Care Excellence (NICE). 2017. Available from: https://www.ncbi.nlm.nih.gov/books/nbk550641 [Last accessed on 2026 May 26]
- [Google Scholar]
- Complex congenital heart defects in children in a resource constraint setting. J Pediatr Neonatal Individ Med. 2019;8:e080212.
- [Google Scholar]
- Global, regional, and national burden of congenital heart disease, 1990-2017: A systematic analysis for the global burden of disease study 2017. Lancet Child Adolesc Health. 2020;4:185-200.
- [CrossRef] [PubMed] [Google Scholar]
- Global, regional, and national burden of congenital heart disease, 1990-2021: A systematic analysis for the global burden of disease study 2021. Eur J Pediatr. 2025;184:253.
- [CrossRef] [PubMed] [Google Scholar]
- Prenatal diagnosis of congenital heart disease: A review of current knowledge. Indian Heart J. 2018;70:150-64.
- [CrossRef] [PubMed] [Google Scholar]
- Critical congenital heart disease in newborn: Early detection, diagnosis, and management. Biosci Med J Biomed Transl Res. 2020;5:107-16.
- [CrossRef] [Google Scholar]
- Pulse oximetry screening for critical congenital heart defects: Effectiveness and implementation across clinical settings. Cardiol Cardiovasc Med. 2025;9:444-56.
- [CrossRef] [PubMed] [Google Scholar]
- Why are congenital heart defects being missed? Ultrasound Obstet Gynecol. 2020;55:747-57.
- [CrossRef] [PubMed] [Google Scholar]
- Impact of prenatal diagnosis of critical congenital heart disease on preoperative and postoperative outcomes. Pediatr Cardiol. 2023;44:1520-8.
- [CrossRef] [PubMed] [Google Scholar]
- Evaluation of fetal echocardiography as a routine antenatal screening tool for detection of congenital heart disease. Cardiovasc Diagn Ther. 2016;6:44-9.
- [Google Scholar]
- Role of routine fetal echocardiography in an unselected group of pregnant women for prenatal detection of cardiac malformations. Indian Heart J. 2020;72:427-30.
- [CrossRef] [PubMed] [Google Scholar]
- Prenatal detection of heart defects in a non-selected population of 30,149 fetuses--detection rates and outcome. Ultrasound Obstet Gynecol. 2006;27:252-65.
- [CrossRef] [PubMed] [Google Scholar]
